GuardXcel™ Cable Glands | Secure Solutions for Engineers
Cable entry, strain relief and enclosure protection options
Amphenol Industrial Operations introduces the GuardXcel® Cable Glands, a comprehensive line of cable glands, vents, and accessories engineered to secure system connections across a multitude of industries. This innovative series offers high-quality protection for system enclosures, connections, and cables, thereby extending the operational life of systems and their components. The GuardXcel® range includes various glands, adapters, multihole seals, and vents, providing end-to-end protection for diverse applications.
At a Glance
- Metric / PG
- Thread options
- NPT / G
- Thread options
- PA 6 / Metal
- Material options
- Multi-hole
- Seal options
- Vents
- Portfolio options
Key Features
Engineer Benefits
Secure Strain Relief & Sealing
Lamellar clamping provides cable retention, strain relief and sealing at the enclosure entry.
- Supports cable retention.
- Reduces strain at connections.
- Helps protect the enclosure entry.
Multiple Thread Options
Metric, PG, NPT and G threads support different enclosure interfaces.
- Matches regional thread standards.
- Fits varied enclosure designs.
- Supports use across global equipment platforms.
Broad Cable Compatibility
The range covers non-armored, armored and shielded cable constructions.
- Supports standard industrial cables.
- Offers options for armored wiring.
- Provides compatible choices for shielded cable entry.
Flexible Seal Solutions
Reducing, flat and multi-hole seals address different cable arrangements.
- Supports reduced cable diameters.
- Accommodates flat cable entries.
- Allows multiple cables through selected glands.
Durable Material Options
Polyamide, nickel-plated brass and stainless steel choices address different mechanical and corrosion requirements.
- Allows material selection for the environment.
- Provides metal options for demanding installations.
- Provides polymer options for standard industrial enclosures.
Applications
Alternative Energy
Solar and wind equipment
eMobility
Automotive wiring
Factory Automation
Machine building; process instrumentation
Power Distribution
Transformers
Rail Mass Transit
Railway systems
Engineer Tips
Continuous temperature
For standard cable glands, distinguish permanent -20°C to +100°C from intermittent -40°C to +150°C; other variants differ.
Thread and cable
Match enclosure thread, cable construction and clamping diameter to the selected part number.
Seal and IP rating
Confirm sealing material and the exact part rating; the portfolio IP range does not apply to every gland.
Approvals
Select railway, EMC, UV and flammability requirements by variant and approval record rather than using a family-wide claim.
Frequently Asked Questions
Which thread types are available?
The range includes Metric, PG, NPT and G / Gas threads; select the thread to match the enclosure.
What are the standard gland temperature limits?
Standard cable glands have permanent -20°C to +100°C and intermittent -40°C to +150°C for standard cable glands. Exact limits depend on the variant.
Can the range accommodate different cable constructions?
Yes. The range covers non-armored, SWA, SWB, AWA, STA and shielded cables, with the appropriate gland and seal selected for each construction.
Technical Highlights
- Cable-entry components; electrical ratings not applicable
- Dimensions: Clamping Range (Cable Diameter): 2.0 mm to 44.0 mm
- Thread Type: Metric (EN 60423)
- Cable Type: Non-armored
- Accessories: Lock Nuts
- Body / Cap: PA 6 (Polyamide 6), Brass (Nickel Plated)
- Seals: CR (Chloroprene), NBR (Nitrile Rubber), Silicone, EPDM
- Lock Nuts (Metal): Brass (Nickel Plated), Stainless Steel
- Operating Temperature (standard cable glands): Permanent: -20°C to +100°C
Specifications
| Not applicable to this product type |
|---|
| Dimensions | Clamping Range (Cable Diameter): 2.0 mm to 44.0 mm |
|---|---|
| Spanner Width: 10.0 mm to 160.0 mm | |
| Outer Diameter (Cap / Body): 15.5 mm to 105.0 mm | |
| Height (Components like washers, nuts): 1.5 mm to 15.0 mm | |
| Height (Cable glands): Up to 118.9 mm | |
| Thread Type | Metric (EN 60423) |
| PG (DIN 40430) | |
| NPT (ANSI B1.20.1) | |
| G / Gas (ISO 228) | |
| Cable Type | Non-armored |
| SWA (Steel Wire Armored) | |
| SWB (Steel Wire Braid) | |
| AWA (Aluminum Wire Armored) | |
| STA (Steel Tape Armored) | |
| Shielded | |
| Accessories | Lock Nuts |
| Multi-hole Seals | |
| Dome Plugs |
| Body / Cap | PA 6 (Polyamide 6), Brass (Nickel Plated) |
|---|---|
| Seals | CR (Chloroprene), NBR (Nitrile Rubber), Silicone, EPDM |
| Lock Nuts (Metal) | Brass (Nickel Plated), Stainless Steel |
| Operating Temperature (standard cable glands) | Permanent: -20°C to +100°C |
|---|---|
| Intermittent: -40°C to +150°C | |
| Flammability | UL94 V2, UL94 HB, EN 45545-2 (R22, R23, HL2, HL3) |
| Ingress Protection Rating | IP54, IP56, IP66, IP67, IP68, IP69K |
| Installation Notes & Remarks | Color Variations Available Upon Request (blue, white, and red (RAL)) |
| Standards & Certifications | UL514B |
| CSA 22.2 No. 18.3-12 | |
| CSA 22.2 No. 94.2-15 | |
| TYPE 4X (UL50E) | |
| Manufactured per DIN EN 62444 / 50262 |
Documents
Catalog or Brochure
| Resource | Download |
|---|---|
| Guardxcel Cable Glands Ic 25 |

Engage with our skilled sales and technical teams who are committed to offering you personalized assistance tailored specifically to your project requirements.