H4 P2KV Solar Connector | Amphe-PV 2000V DC
2000V DC photovoltaic connections for 6 AWG cable
The H4 P2KV Solar Connector from Amphenol Industrial Operations is engineered for next-generation utility-scale and commercial photovoltaic systems requiring certified 2000V DC performance, increased current capacity, and dependable outdoor reliability. Designed for 6 AWG (16 mm²) photovoltaic cable, the Amphe-PV H4 P2KV supports longer PV strings, reduced electrical losses, and lower balance-of-system complexity while maintaining compatibility with designated connectors in the Amphenol H4 family.
As solar projects move beyond conventional 1500V architectures, engineers need connectors specifically designed to manage higher operating voltages without compromising electrical efficiency, environmental sealing, or installation consistency. The H4 P2KV Solar Connector provides a certified high-voltage connection platform with low contact resistance, durable materials, dedicated installation tooling, and field-installable or preassembled options for demanding solar energy systems.
At a Glance
- 2000V DC
- UL 6703
- 6 AWG / 16 mm²
- PV cable
- ≤0.25 mΩ
- Contact resistance
- IP2X
- Unmated
- UL94-V0
- Flame class
Key Features
Engineer Benefits
Rated for 2000V DC under UL 6703, with ETL and TÜV certification
Designed for emerging 2000V DC photovoltaic architectures. The complete system must be approved for 2000V operation.
- Supports longer PV strings where system design permits.
- Can reduce balance-of-system component quantities.
- Can lower current for a given transmitted power.
Designed for 6 AWG / 16 mm² photovoltaic cable
Supports 6 AWG / 16 mm² photovoltaic cable with an outside diameter of 8.38–11.0 mm.
- Accommodates larger conductors for high-current DC paths.
- Supports utility-scale PV string connections.
- Fits approved cables across the published diameter range.
Typical contact resistance of ≤0.25 mΩ for reduced power loss
A low-resistance interface limits connection losses and heat generation.
- Reduces resistive power loss at the connection.
- Limits heat generated at the interface.
- Supports energy production across arrays with many connections.
Mating compatible with designated connectors in the Amphenol H4 connector family
Designated H4-family connectors can mate mechanically. Final connection voltage is limited by the lower-rated component.
- Builds on an established solar connector interface.
- Supports integration with approved H4 combinations.
- Allows reuse of the family interface during platform transitions.
IP65/IP68 when mated IP2X when unmated
Correctly assembled and fully mated connectors provide IP65/IP68 sealing; unmated connectors provide IP2X touch protection.
- Resists dust ingress when mated.
- Protects the mated interface against water ingress.
- Reduces access to contacts when unmated.
UV Resistance
UV-resistant thermoplastic insulation, a UL94-V0 flame classification, and an ambient temperature range of -40°C to +85°C support installation in demanding outdoor photovoltaic environments.
- Resists outdoor solar exposure.
- Supports flame-retardant enclosure requirements.
- Supports PV installations across the published ambient range.
As solar projects move beyond conventional 1500V architectures, engineers need connectors specifically designed to manage higher operating voltages without compromising electrical efficiency, environmental sealing, or installation consistency. The H4 P2KV Solar Connector provides a certified high-voltage connection platform with low contact resistance, durable materials, dedicated installation tooling, and field-installable or preassembled options for demanding solar energy systems.
Applications
Alternative Energy
Solar — utility-scale, commercial and industrial PV; module strings; combiner and inverter interfaces
Energy Storage
Solar-plus-storage infrastructure
Engineer Tips
Voltage of the pair
Use approved P2KV pairs for 2000V systems. Mating to a standard 1500V H4 Plus component limits the connection to 1500V.
Cable selection
Match 6 AWG / 16 mm² cable and the 8.38–11.0 mm cable diameter to the exact approved configuration.
Current conditions
Evaluate 65A ETL / 70A TÜV at 85°C against the approved cable, ambient conditions, installation and derating requirements.
Safe servicing
Isolate and de-energize the circuit before mating, unmating or service; use approved assembly instructions and protective caps.
Frequently Asked Questions
What voltage is the H4 P2KV Solar Connector rated for?
The connector is rated for 2000V DC photovoltaic applications under UL 6703. It also has a rated impulse voltage of 16 kV under applicable IEC criteria.
What is the current rating of the H4 P2KV connector?
The documented current ratings at 85°C are 65A under ETL and 70A under TÜV. Final current capability depends on the approved cable, ambient temperature, installation conditions, and applicable derating requirements.
What cable size does the H4 P2KV Solar Connector support?
The connector is designed for 6 AWG or 16 mm² photovoltaic copper cable. The documented cable outside-diameter range is 8.38 mm to 11.0 mm, with conductor constructions ranging from 7 to 128 strands.
Is the H4 P2KV connector touch-safe when unmated?
Yes. The connector is rated IP2X in the unmated condition. The circuit must still be isolated and de-energized before assembly, mating, unmating, or service.
Is the H4 P2KV compatible with other H4 connectors?
It is designed for mating compatibility with designated products in the Amphenol H4 connector family. Engineers should verify the exact approved combination using current Amphenol documentation. Compatibility with connectors from other manufacturers should not be assumed.
Mating Compatibility
Important Compatibility Note: The H4 P2KV is currently Amphenol’s only H4 connector qualified for 2000V DC operation and is designed specifically for 6 AWG (16 mm²) photovoltaic cable. All other standard H4 Plus connectors are rated for 1500V DC. If an H4 P2KV connector is mated with a standard 1500V H4 Plus connector, the connection is limited to the lower-rated component and must be considered a 1500V connection, not a 2000V connection. Always use approved H4 P2KV connector pairs when designing or installing 2000V photovoltaic systems.
Technical Highlights
- Voltage: 2000V DC, UL 6703
- Current Rating: 65A ETL; 70A TÜV at 85°C
- Certifications: ETL and TÜV certification; 2000V DC under UL 6703
- Touch proof: IP2X when unmated
- Cable O.D.: Ø8.38 mm to Ø11.0 mm
- Wire size (mm²): 6 AWG / 16 mm²
- Locking element: Snap locking
- Contact plating: Tin-plated
- Contacts: Copper Alloy
- Shell: Thermoplastic (PC/PA)
- Temperature range: -40°C to 85°C
Specifications
| Voltage | 2000V DC, UL 6703 |
|---|---|
| Current Rating | 65A ETL; 70A TÜV at 85°C |
| Certifications | ETL and TÜV certification; 2000V DC under UL 6703 |
| Touch proof | IP2X when unmated |
| Cable O.D. | Ø8.38 mm to Ø11.0 mm |
|---|---|
| Wire size (mm²) | 6 AWG / 16 mm² |
| Locking element | Snap locking |
| Contact plating | Tin-plated |
|---|---|
| Contacts | Copper Alloy |
| Shell | Thermoplastic (PC/PA) |
| Temperature range | -40°C to 85°C |
|---|---|
| Flammability | UL94 V-0 |
| Protection class | IP65/IP68 when mated; IP2X when unmated |
| RoHS | Yes |
| REACH | Yes |
| Rated Impulse Voltage | 16 kV, IEC |
|---|---|
| Typical Contact Resistance | ≤0.25 mΩ |
| Conductor Construction | 7 to 128 strands |
| Connection Type | Crimp termination |
| Upper Limiting Temperature | 115°C |
| Safety Class | Class II |
| Application Class | Class A |
| Overvoltage Category | Category III |
| Pollution Degree | Degree 3; degree 2 inside an enclosure |
Documents
Data sheets
| Resource | Download |
|---|---|
| H4 Plus P2kv Connector Ids 118 |
Application Notes
| Resource | Download |
|---|---|
| H4 Plus P2kv Connectors Ian 146 |
Assembly Instructions
| Resource | Download |
|---|---|
| H4 Plus P2kv Assembly Instructions Ai 29 |

Engage with our skilled sales and technical teams who are committed to offering you personalized assistance tailored specifically to your project requirements.