EMI Wind-Lok®| High Vibration Connector
Shielded reverse-bayonet power connections for wind systems
EMI Wind-Lok Wind Turbine Connector for Reliable Performance
At a Glance
- 1
- Power contact
- ⅓ turn
- Reverse bayonet
- 2000
- Mating cycles
- Secondary
- Locking
- Silver
- Contact plating
Key Features
Engineer Benefits
1/3 Turn Reverse Bayonet
A one-third-turn reverse bayonet provides quick power connection.
- Speeds connection and disconnection.
- Provides secure mechanical engagement.
- Simplifies access during service.
Secondary Locking
Secondary locking helps maintain the engaged connection.
- Helps resist accidental disconnection.
- Maintains engagement under vibration.
- Supports dependable field connections.
Crimp or Busbar Termination
Crimp and busbar terminations address cable and power-distribution layouts.
- Connects modular power-distribution elements.
- Reduces separate cable junctions.
- Supports compact busbar layouts.
Touch-Proof
Touch-proof construction limits access to conductive parts.
- Limits access to conductive parts.
- Supports safer equipment interfaces.
- Reduces accidental contact during handling.
2000 Mating Cycles
Durability is 2000 mating cycles.
- Supports repeated service connections.
- Reduces replacement frequency within rated use.
- Provides a durability basis for maintenance planning.
Applications
Alternative Energy
Wind turbine nacelles; pitch systems; solar inverters
Energy Storage
BESS and hybrid power converters
Heavy Equipment
High-power rugged equipment
Engineer Tips
Rated configuration
Verify the selected contact, cable and current derating against the approved drawing.
Shield continuity
Plan the connector-to-cable and enclosure shield path for EMI performance.
Sealing
Confirm the assembled ingress rating, cable gland and environmental test conditions for the selected part.
Cable fit
Match the approved contact barrel and cable gland to the actual conductor and cable outside diameter.
Frequently Asked Questions
How does the connector mate?
A one-third-turn reverse bayonet provides quick power connection.
How is the connection retained?
Secondary locking helps maintain the engaged connection.
How can the interface connect to power distribution?
Crimp and busbar terminations address cable and power-distribution layouts.
Design and Integration
Engineered with comprehensive electromagnetic interference (EMI) shielding, the EMI Wind-Lok safeguards critical power and signal systems from external and internal noise. This is essential for ensuring stable turbine operation and maintaining signal integrity in complex wind power installations. The shielded construction reduces crosstalk, minimizes downtime, and meets the performance requirements of today’s smart grid and control architectures.
Wind turbine environments are characterized by constant motion and variable loading conditions. The EMI Wind-Lok connector incorporates a secure bayonet coupling system that resists vibration-induced loosening and provides tactile feedback during installation. This feature, combined with an anti-decoupling mechanism, ensures long-term mechanical stability even under the harshest dynamic stresses.
Optional integration of Amphenol’s proprietary RADSOK® contact technology allows the EMI Wind-Lok to handle higher current ratings with lower contact resistance. RADSOK® contacts are known for their robust performance in demanding electrical environments, offering improved heat dissipation, lower mating forces, and a longer operational lifespan. This makes the connector suitable for large-scale wind power platforms where high efficiency and reliability are mission critical.
Technical Highlights
- Voltage: 1000V
- Current Rating: Up to 800A
- Number of contacts: 1
- EMI: Yes
- Cable O.D.: 32-38mm
- Mating cycles: 2000
- Wire size (mm²): 4/0- 777 KCMIL
- Locking element: Secondary locking
- Contact plating: Silver
- Contacts: Copper
- Sealing components: Rubber
- EMI components: Copper
Specifications
| Voltage | 1000V |
|---|---|
| Current Rating | Up to 800A |
| Number of contacts | 1 |
| EMI | Yes |
| Touch proof | Yes |
| Cable O.D. | 32-38mm |
|---|---|
| Mating cycles | 2000 |
| Wire size (mm²) | 4/0- 777 KCMIL |
| Locking element | Secondary locking |
| Contact plating | Silver |
|---|---|
| Contacts | Copper |
| Sealing components | Rubber |
| EMI components | Copper |
| Shell | Aluminum |
| Temperature range | -40ºC to +125ºC |
|---|---|
| Protection class | IP67 |
| RoHS | Yes |
| REACH | Yes |
| Published feature | 300 day salt spray rating using Black Anodized finish |
|---|---|
| Body ingress protection | IP67 and IP69K |
| Body conductor size | up to 70 mm² |
| Body shell options | thermoplastic or metal shell housing options |
Documents
Data sheets
| Resource | Download |
|---|---|
| Emi Wind Lok Series Connectors Ids 105 |
Application Notes
| Resource | Download |
|---|---|
| Emi Wind Lok Ian 113 |
Assembly Instructions
| Resource | Download |
|---|---|
| Wind Lok Series Assembly Instructions Ai 8 |

Engage with our skilled sales and technical teams who are committed to offering you personalized assistance tailored specifically to your project requirements.